Date: 2020-09-07

Project Overview

  • Project Name: Project No. PW12009029
  • Location: Suqian City, Jiangsu Province, China
  • System Process: MMF + ACF + 2RO + EDI + SMB (per train)
  • Production Capacity: 2×60 T/H (relocated) + 2×60 T/H (new), 240 T/H total
  • Water Quality Standard: Ultrapure water, 18 MΩ·cm class (EDI + mixed-bed polishing)

System Scope:

  • Two relocated 60 T/H ultrapure water trains (equipment reuse)
  • Two brand-new 60 T/H ultrapure water trains

Client Profile

The end client is one of the world’s leading photovoltaic companies, and the project site is one of its major high-efficiency cell manufacturing centers in China. Large-format, high-efficiency cell lines require extensive ultrapure water for wet-chemical processing.

In accordance with the client’s confidentiality requirements, the customer name is withheld in this case study and the project is referenced by its contract number.

Technical Note: Process Terms

For your reference, here is a breakdown of the technical process mentioned:

  • MMF: Multi-Media Filter — removes suspended solids and turbidity from feed water through layered filtration media (anthracite, sand and garnet).
  • ACF: Activated Carbon Filter — removes residual chlorine, organic matter, color and odor to protect downstream membranes and ion-exchange resins.
  • 2RO: Two-stage Reverse Osmosis — two RO passes in series, producing water of significantly higher purity and lower conductivity.
  • EDI: Electrodeionization — a continuous, chemical-free polishing process that combines ion exchange with electrical regeneration to produce high-resistivity water.
  • SMB: Secondary Mixed Bed — a polishing mixed-bed ion exchanger, typically the final stage that lifts water resistivity to 18 MΩ·cm.

Project Location: Suqian City, Jiangsu Province, China | System process: MMF + ACF + 2RO + EDI + SMB (per train) | Date: 2020-09-07

“